You can find your fuse at the left hand side of the terminal area (where the wires are) of your controller.
It should have a single filament running through it, if this is absent or broken the fuse must be replaced.
Our controllers use a 1amp 20mm glass fuse, these are available at most of our retailers
- If the fuse has blown, this is likely being caused by damage to a wire. Check that the wiring on each STATION (and solenoid) is intact and not damaged - this may be between the controller and the solenoid in your garden.
- If your fuse is continuously blowing, remove all wires from every STATION on the controller and reconnect each station one at a time to determine which STATION is causing the fault - then you'll need to check the coil for that solenoid (cylinder with wires coming from it on your solenoid), and it's field wire.
Comments
0 comments